An experimental study of cyclically loaded monopod caisson foundations for offshore wind turbines
DOI:
https://doi.org/10.21703/0718-2813.2006.1.3705Keywords:
caisson foundation, cyclic loading, masing rule, uplift, settlementAbstract
Suction caissons may be used in the future as foundations for offshore wind turbines. The research programme includes laboratory testing, larger scale field testing and theoretical modelling. This paper concentrates on the experimental results obtained in combined CYCLIC loading tests on monopod caissons. Results obtained for different values of vertical load are presented and interpreted. They proved to obey the Masing rule. Caisson uplift or settlement was found to be a function of the vertical load.
References
Byrne, B. W. and Houlsby, G. T. (2003). Foundations for offshore wind turbines. Phil. Trans. R. Soc. London, Series A 231, 2909- 2300. DOI: https://doi.org/10.1098/rsta.2003.1286
Downloads
Published
Issue
Section
License
Copyright (c) 2006 Universidad Católica de la Santísima Concepción

This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.