Experimental analysis of the seismic isolation of a tank with liquid using a geosynthetics interface

Authors

  • Rodrigo Betanzo Departamento Civil, Parés y Álvarez, Chile
  • Fernando Cerda University of Concepción image/svg+xml
  • José Luis Almazán Pontifical Catholic University of Chile image/svg+xml

DOI:

https://doi.org/10.21703/0718-2813.2011.9.3590

Keywords:

isolation, shaking table, geosynthetics interface, tank with liquid

Abstract

An interface composed of synthetic materials such as high-strength nonwoven geotextiles and Ultra High Molecular Weight PolyEthylenes (UHMWPE), placed underneath foundations of structures can provide seismic protection. This is achieved by dissipating energy to the superstructure through a controlled sliding between these two surfaces. Shaking table tests were performed to a storage tank with mat foundation and with and without water conditions. Harmonic and two directional seismic excitations were used for describing the dynamic response of the system. The results showed that the tank isolated with the geosynthetic interface suffered a remarkable reduction in the transmitted accelerations from the excitation. Accompanying these reductions slip deformations took place along the interface. In addition, lesser water pressures in the inner wall were measured in comparison with the tank without geosynthetic isolation. The experimental results demonstrate the technical feasibility of this isolation system, which allows its easy implementation and cost-effective relationship to be used in earthquake hazard mitigation.

References

Betanzo, R. (2007). Sistema de protección sísmica utilizando interfaz de geosintéticos. Aplicación experimental a estanque de almacenamiento con apoyo continuo. Memoria para optar al título de Ingeniero Civil, Universidad de Concepción, Chile

Cerda, F. (2006). Protección sísmica para estanques de acero inoxidable, pared delgada y apoyos. Tesis de Magíster, Pontificia Universidad Católica, Chile

Negussey D., Wijewickreme W.K.D. and Vaid Y.P. (1989). Geomembrane interface friction. Canadian Geotechnical Journal 26:165-169

Yegian, M.K. and Kadakal, U. (2004). Foundation Isolation for Seismic Protection using a smooth Synthetic Liner. Journal of Geotechnical and Geoenvironmental Engineering 130, No 11:1121-1130

Yegian, M.K. and Lahlaf A.M. (1992). Dynamic interface shear strength properties of geomembranes and geotextiles. Journal of Geotechnical Engineering 118, No 5:760-779

Williams, N.D. and Houlihan, M. (1986). Evaluation of friction coefficients between geomembranes, geotextiles and related products. Proceedings Third International Conference on Geotextiles, Vienna, Austria, Vol. 3, 891-896

Downloads

Published

2011-06-01

Issue

Section

Articles

How to Cite

Experimental analysis of the seismic isolation of a tank with liquid using a geosynthetics interface. (2011). Obras Y Proyectos, 9, 23-29. https://doi.org/10.21703/0718-2813.2011.9.3590