Efficiency of a tuned liquid column damper considering a seismic excitation of high frequency content and uncertainty

Authors

DOI:

https://doi.org/10.4067/S0718-28132021000100067

Keywords:

TLCD, Parameter uncertainty, Stochastic analysis, High frequency content

Abstract

In this research the behaviour of a one degree of freedom structure controlled by an optimal tuned liquid column damper (TLCD) and subjected to stochastic seismic excitations of high frequency content is studied. Uncertainty is introduced in some system parameters. The influence on the behaviour of the optimal TLCD parameters, on the efficiency measured as reduction of main system displacement and on the root mean square (RMS) displacement of the structure is analysed. An equivalent statistical linearization is performed to include the non-linear nature of the TLCD. The optimal TLCD parameters are the frequency ratio and the pressure drop coefficient. TLCD optimization is performed by minimizing the standard deviation reduction of mainframe displacement. The uncertainty is entered into the mass ratio, length ratio, and head loss coefficient. The behaviour of the efficiency is analysed, measured as a percentage reduction of the displacement when including an optimal TLCD and the RMS of the displacement, before the inclusion of uncertainty in the aforementioned parameters. It is found that the introduction of uncertainty in the period of the structure produces the highest sensitivity in the optimal parameters of the TLCD, the efficiency and the RMS of the displacement of the structure. This occurs mainly in rigid structures and with a small mass ratio. On the other hand, an uncertainty in the mass ratio, and length ratio of the TLCD does not produce variations in the efficiency or in the RMS of displacement of the structure.

References

Balendra, T., Wang C.M. and Cheong, H.F. (1995). Effectiveness of tuned liquid column dampers for vibration control of towers. Engineering Structures 17(9), 668-675.

Chakraborty, S., Debbarma, R. and Marano, G.C. (2012). Performance of tuned liquid column dampers considering maximum liquid motion in seismic vibration control of structures. Journal of Sound and Vibration 331(7), 1519–1531.

Debbarma, R., Chakraborty, S., and Ghosh, S.K. (2010) Optimum design of tuned liquid column dampers under stochastic earthquake load considering uncertain bounded system parameters. International Journal of Mechanical Sciences 52(10), 1385-1393.

Di Matteo, A., Lo Iacono, F., Navarra, G. and Pirrotta, A. (2015). Optimal tuning of tuned liquid column damper systems in random vibration by means of an approximate formulation. Meccanica 50(3), 795-808.

Espinoza, G., Quinteros, C., Gajardo, K., Suazo, A. y Quijada, S. (2021). Eficiencia de un amortiguador de columna de líquido sintonizado considerando una excitación sísmica de bajo contenido de frecuencias e incertidumbre. Obras y Proyectos 29, 54-66.

Espinoza, G., Sagredo, G. y Suazo, A. (2020a). Análisis de la eficiencia de un amortiguador combinado sintonizado con incertidumbre en los parámetros sometido a una excitación sísmica de alto contenido de frecuencias. Obras y Proyectos 28, 58-67.

Espinoza, G., Rivas, S. y Suazo, A. (2020b). Análisis de la eficiencia de un amortiguador combinado sintonizado con incertidumbre en los parámetros sometido a excitaciones sísmicas de bajo contenido de frecuencias. Obras y Proyectos 28, 68-77.

Espinoza, G., Carrillo, C. and Suazo, A. (2018). Analysis of a tuned liquid column damper in non-linear structures subjected to seismic excitations. Latin American Journal of Solids and Structures 15(7), e91.

Lee, S.K., Lee, H.R. and Min, K.W. (2010). Experimental verification on nonlinear dynamic characteristic of a tuned liquid column damper subjected to various excitation amplitudes. The Structural Design of Tall and Special Buildings 21(5), 374–388.

NCh2745 (2013). Análisis y diseño de edificios con aislación sísmica. Instituto Nacional de Normalización INN, Santiago, Chile.

NCh433 (2009). Diseño sísmico de edificios. NCh433 Of.1996 mod.2009. Instituto Nacional de Normalización INN, Santiago, Chile.

Pabarja, A., Vafaei, M., Alih, S.C., Md Yatim, M.Y. and Osman, S.A. (2019). Experimental study on the efficiency of tuned liquid dampers for vibration mitigation of a vertically irregular structure. Mechanical Systems and Signal Processing 114, 84–105.

Rozas, L., Boroschek, R.L., Tamburrino, A. and Rojas, M. (2016). A bidirectional tuned liquid column damper for reducing the seismic response of buildings. Structural Control and Health Monitoring 23(4), 621-640.

Saitua, F., Lopez-Garcia, D. and Taflanidis, A.A. (2018). Optimization of height-wise damper distributions considering practical design issues. Engineering Structures 173,768-786.

Sakai, F., Takaeda, S. and Tamaki, T. (1989). Tuned liquid column damper - New type device for suppression of building vibrations. First International Conference on High-Rise Buildings, Nanjing, China, 926-931.

Shum, K.M. and Xu, Y.L. (2002). Multiple-tuned liquid column dampers for torsional vibration control of structures: experimental investigation. Earthquake Engineering and Structural Dynamics 31(4), 977-991.

Shum, K.M. (2009). Closed form optimal solution of a tuned liquid column damper for suppressing harmonic vibration of structures. Engineering Structures 31(1), 84-92.

Zhu, F., Wang, J.T., Jin, F. and Altay, O. (2015). Real-time hybrid simulation of single and multiple tuned liquid column dampers for controlling seismic-induced response. 6th International Conference on Advances in Experimental Structural Engineering, University of Illinois, Urbana-Champaign, USA.

Downloads

Published

2021-06-30

Issue

Section

Articles

How to Cite

Efficiency of a tuned liquid column damper considering a seismic excitation of high frequency content and uncertainty. (2021). Obras Y Proyectos, 29, 67-79. https://doi.org/10.4067/S0718-28132021000100067